Scandinavian Distributor of Medical Diagnostic and Life Science Products

Infectious Disease



In this product group customers will find a broad range of PCR diagnostic kits, both in singleplex and multiplex formats for the identification of infections including sexually transmitted diseases, HPV, torch infections, herpes, intestinal infections, respiratory infections, purulent septic infections, neuro infections, hepatitis, HIV and others.


Key advantages of kits include:

  • All kits contain an Internal Control which monitors the extraction efficiency and PCR process and checks for possible PCR inhibition.
  • Many kits are supplied with a positive control allowing for quality control of the analysis.
  • Single target kits have simultaneous amplification (multiplex) of DNA/RNA from pathogen and internal control in one PCR tube.
  • Multiplex kits use primers and probes for several (for up to 5) DNA targets in one tube. Amplification products identification runs for each DNA target on a different optical channel.
  • For most kits, complete detection occurs in one hour.
  • Good sensitivity and quality and high stability of reagents.
  • Kits available in aliquoted and non-aliquoted formats.
  • Compatibility of kits with a broad range of instruments.

Hepatitis Virus Infections + HIV

Amplisens® HCV/HBV/HIV Multiplex Kit

Amplisens® HCV/HBV/HIV multiplex FRT PCR kit is a multiplex PCR kit for the qualitative detection of HCV/HBV/HIV in one reaction. Kit contains an Internal Control in order to check RNA isolation and reverse transcription processes of each individual samples and to identify possible amplification reaction inhibition.


The analytical sensitivity of the kit depends on the clinical sample and is for HCV 100 IU/ml (sample vol. 100 µl) or 10 IU/ml (sample vol. 1 000 µl), for HBV 50 IU/ml (sample vol. 100 µl) or 5 IU/ml (sample vol. 1 000 µl), for HIV 200 copies/ml (sample vol. 100 µl) or 20 copies/ml (sample vol. 1 000 µl). For detection, 4 channels- FAM/Green, JOE/Yellow/HEX, ROX/Orange and Cy5/Red are needed. DNA/RNA isolation is not provided with the kit. However, reverse transcription kit is included.



Amplisens® HBV/HDV Multiplex Kit


Amplisens® HBV/HDV multiplex FRT PCR kit is a multiplex PCR kit for the detection of HBV/HDV in one reaction. The analytical sensitivity of the kit is for HBV 100 IU/ml (sample vol. 100 µl) or 50 IU/ml (sample vol. 200 µl), for HDV 100 copies/ml (sample vol. 100 µl) or 50 copies/ml (sample vol. 200 µl) or 10 copies/ml (sample vol. 1 µl). For detection, 3 channels- FAM/Green, JOE/Yellow/HEX, and ROX/Orange are needed. DNA/RNA isolation is not provided with the kit. However, reverse transcription kit is included.



Amplisens® Genoscreen IL28B-FL Multiplex Kit


Amplisens® Genoscreen IL28B-FL is a multiplex PCR test for detection of SNP rs8099917 and rs12979860 in Interleukin 28B gene. The analytical sensitivity is no less than 5 x 103 copies/ml. For detection, 3 channels- FAM/Green, JOE/Yellow/HEX, and ROX/Orange are needed. DNA isolation is not provided with the kit.



Singleplex Kits for Hepatitis + HIV


Singleplex kits are also available for:

  • Hepatitis A, B, C, D, G
  • HIV
  • HIV associated infections: Cryptococcus neoforms, Pneumocystis jirovecii (carinii), Drug resistant mutations (HLA B*5701)

Contact Biotech-IgG for more information.



Sexually Transmitted Infections

 



Amplisens® multiplex C. trachomatis / T. vaginalis / N. Gonorrhoeae


Amplisens® multiplex C. trachomatis / T. vaginalis / N. Gonorrhoeae PCR kit is for the quantitative detection of Chlamydia tachomatis, Trichomonas vaginalis and Neisseria gonorrhoeae in one reaction. Kit contains an Internal Control in order to check DNA isolation and to identify possible amplification reaction inhibition. Reagents can be ordered in aliquoted and non-aliquoted formats (110 reactions/kit).


The analytical sensitivity is 5 x 102 copies/ml for all pathogens. For detection, 4 channels- FAM/Green, JOE/Yellow/HEX, ROX/Orange and Cy5/Red are needed. DNA isolation is not provided with the kit.


Amplisens® multiplex C. trachomatis / Ureaplasma / M.hominis


Amplisens® multiplex C. trachomatis / Ureaplasma / M.hominis PCR kit is for the quantitative detection of Chlamydia tachomatis, Ureaplasma spp. and Mycoplasma hominis in one reaction. Kit contains an Internal Control in order to check DNA isolation and to identify possible amplification reaction inhibition. Reagents can be ordered in aliquoted and non-aliquoted formats (110 reactions/kit).


The analytical sensitivity is 5 x 102 copies/ml for Chlamydia tachomatis and 1 x 103 copies/ml for Ureaplasma and M. hominis. For detection, 4 channels- FAM/Green, JOE/Yellow/HEX, ROX/Orange and Cy5/Red are needed. DNA isolation is not provided with the kit.


Amplisens® multiplex C. trachomatis / Ureaplasma /M.genitalium / M.hominis 


Amplisens® multiplex C. trachomatis / Ureaplasma /M.genitalium / M.hominis PCR kit is for the quantitative detection of Chlamydia tachomatis, Ureaplasma spp., Mycoplasma genitalium and Mycoplasma hominis in one reaction. Kit contains an Internal Control in order to check DNA isolation and to identify possible amplification reaction inhibition. Reagents can be ordered in a non-aliquoted format (110 reactions/kit).


The analytical sensitivity is 5 x 102 copies/ml for all pathogens. For detection, 5 channels- FAM/Green, JOE/Yellow/HEX, ROX/Orange, Cy5/Red and Cy5.5/Crimson are needed. DNA isolation is not provided with the kit.


Singleplex kits for Sexually Transmitted Infections


Many more multiplex kits are available and singleplex kits for:

  • Chlamydia trachomatis
  • Neisseria gonohoeae
  • Treponema pallidum
  • Trichomonas vaginalis
  • Mycoplasma genitalium
  • Mycoplasma hominis
  • Ureaplasma species
  • Gardnerella vaginalis
  • Candida albicans
  • Floroscenosis

Contact Biotech-IgG for more information.


Download information brochure STD Diagnostics brochure.


Herpes Virus Infections



Amplisens® multiplex EBV/CMV/HHV6-screen-FRT

  • The most effective kit for determination of viral load.
  • All pathogens are detected in quantitative format.
  • One protocol for both liquid samples (blood, urine, saliva) and biopsy (solid) samples.
  • Two independent internal controls for quantifying virus in liquid samples & biopsy samples.
  • Analytical sensitivity: 400 copies/ml (liquid) and 5 copies/105 cells (biopsy).
  • Ideal for transplant patient screening.
  • 110 rxns per kit
  • 4 channels- FAM/Green, JOE/Yellow/HEX, ROX/Orange and Cy5/Red

Download information brochure Herpes Virus Infection.


Neuro Infections

Amplisens® multiplex N. meningitidis/ H. influenzae/ S. Pneumoniae


Kit contains an Internal Control in order to check DNA isolation and to identify possible amplification reaction inhibition. Reagents  available in non-aliquoted format (55 reactions/kit).

The analytical sensitivity is 1 x 103 copies/ml for all pathogens. For detection, 2 channels- FAM/Green and JOE/Yellow/HEX are needed. DNA isolation is not provided with the kit.


Human Papilloma Virus (HPV) Infections



More than 40 HPV types are sexually transmitted and some cause cervical cancer and other types of cancer. These are called high-risk (about 13 types), oncogenic or carcinogenic HPV 19s. Other sexually transmitted types of HPV do not appear to cause cancer and are called low-risk HPVs.


Amplisens® multiplex HPV HCR Genotype titre FRT

  • Detection, differentiation & quantitation of 14 HPV HCR types: 16,18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68
  • Distinction between clinically relevant and irrelevant HPV HCR load (per 105 human cells)
  • Internal control based on human ;2-globin gene detection
  • Evaluation of clinical sample quality-elimination of false negative results
  • Ideal for detectionand early cervical per-cancer and cancer diagnostics
  • Analytical sensitivity: 1 x 103 copies/ml
  • 110 rxns per kit
  • 4 channels- FAM/Green, JOE/Yellow/HEX, ROX/Orange and Cy5/Red
  • CE marked

Download information brochure HPV HCR Genotyping.


Amplisens® Low-Risk HPV kit

  • Type HPV-6 and HPV-11
  • Analytical sensitivity: 1 x 103 copies/ml
  • Internal control based on human ;2-globin gene detection
  • 120 rxns per kit

Download information brochure HPV Diagnostics.

Ebola



Ebola Zaire PCR kit

  • Brand new qualitative Real-time kit for Ebola Zaire virus detection
  • Detection of Ebola virus in wide spectrum of biological clinical material (blood, urine, saliva, tissue)
  • 100% specificity, sensitivity not less than 400 copies/ml

Download information brochure Ebola Zaire.



Below is a list of our most popular kits within Infectious Disease. For a complete list of products, please use product search at the top of the page.



Product Description Product Code
Amplisens HCV/HBV/HIV FRT PCR Kit (RUO) R-V50-4x(RG, iQ, Mx, Dt)-CE Enquiry
Amplisens HBV/HDV FRT PCR Kit (RUO) R-V56(RG, iQ, Mx, Dt)-CE Enquiry
Amplisens Genoscreen IL28B (IVD CE) R-O5-100-F(RG, iQ, Dt, CFX) Enquiry
Amplisens C. trachomatis / T. vaginalis / N. Gonorrhoeae Kit (IVD CE)  R-B83-F(RG,iQ)-CE Enquiry
Amplisens C. trachomatis / Ureaplasma / M.hominis Kit (IVD CE) R-B43-F(RG,iQ)-CE
Enquiry
Amplisens C. trachomatis / Ureaplasma /M.genitalium / M.hominis Kit (IVD CE)
R-B60-F(RG)-CE Enquiry

Amplisens EBV/CMV/HHV6-screen-FRT Kit (IVD CE)

R-V48(RG, iQ, Mx)-CE Enquiry

Amplisens N. meningitidis/ H. influenzae/ S. Pneumoniae Kit (IVD CE)

R-B25(RG, iQ)-CE Enquiry

Amplisens High-Risk HPV HCR Genotype titre FRT Kit (IVD CE)

R-V67-F-CE Enquiry

Amplisens Low-Risk HPV Kit (IVD CE)

R-V11(RG, iQ, Mx)-CE Enquiry